Environmental testing requirements: Meet the requirements of Group I of Climate Environmental Testing, Group I of Mechanical Environmental Testing in GB/T 14710-2009, and Table 3 of this technical requirement. The transportation test and power supply voltage adaptability test of the analyzer should comply with the requirements of Chapter 4 and Chapter 5 of GB/T 14710-2009, respectively.
Safety requirements: Meet the requirements of applicable clauses in GB 4793.1-2007, GB 4793.9-2013, and YY0648-2008.
Electromagnetic compatibility requirements: comply with the requirements of applicable clauses in GB/T18268.1-2010 and GB/T18268.26-2010.

Ứng dụng:

STS-A200 Specific Protein Analyzer
The specific protein analyzer uses scattering turbidimetry to determine the reaction between antigens and antibodies, and the rate method is used during the measurement process. Compared to other measurement methods, this method has higher sensitivity and faster detection speed, and is not affected by background scattering signals. Specific protein analyzer is mainly used to measure the content and activity of specific protein molecules in biological samples such as serum and plasma, and the interaction between these protein molecules and other molecules (such as antibodies and ligands). It can be used to detect tumor markers, infectious diseases markers, cardiovascular disease markers, etc., and dynamically monitor the content and change trend of these markers, Improve early diagnosis of diseases and assess treatment outcomes. In addition, specific protein analyzers can also be used for drug screening and efficacy evaluation research.
Application field: hospital; Health center; laboratory; Animal Hospital
Instrument size: ≤ 60cm * 40cm * 52cm;
Analysis method: rate scattering turbidity method or projection turbidity method;
Optical system: 12V long-life halogen lamp, using beam type holographic backscatter grating technology, supporting a total of 8 wavelengths from 340-700nm;
Intended product use: for the determination of specific proteins in human body fluid samples;
Reaction system: standard with 40 UV transparent reaction cups; A constant temperature control reaction system at 37 ± 0.1 ℃, using solid direct thermal control technology; Full surround temperature sensor daily maintenance free;
Sample rack injection system: 5-well sample rack rail continuous injection, with a maximum injection volume of 25 samples; The sampling needle has functions such as needle blockage alarm, automatic liquid level detection, collision prevention, and quantity tracking;
Data processing: Built in scanning function, automatically adding sample information, managing patient information, sending results to LIS, storing and monitoring test results, querying results, and printing results;
Sampling needle and sampling system: using ceramic core micro plunger pump for injection, high precision, wear resistance, maintenance free, and long service life;
Mixing system: stainless steel micro spiral surface special treatment, stirring evenly without spillage or foaming, easy to clean and less polluting;
Cleaning system: The reaction cup is automatically cleaned with warm water, and the degree of cleaning is automatically detected and fed back to the upper computer.
Product Similar
DR100 Direct Reading Ferrograph Model: DR100 (1) Can quickly measure the content of all ferromagnetic wear particles in oil, and provide quick quantitative analysis for ferromagnetic particles in oil. (2) By utilizing equipment to detect changes in wear intensity at an early stage of wear, and adjusting the sampling monitoring time density, trend analysis can be conducted on the instrument and equipment to further inspect and replace the problem, avoiding serious losses.

0765 259 545

RF500 Rotary Particle Depositor Model: RF500 The RF500 dual rotary ferrograph is a new type of equipment operating condition oil analysis instrument, which meets the requirements of NB/T 51068-2017 "Iron spectrum analysis method for gear oil in coal mine oil equipment (rotary ferrograph method)" and Q-SH.J 014-2010 "Technical standard for iron spectrum analysis of coal mine equipment oil".

0765 259 545

Glow spectrometer Model: GDS8000 GD OES Complies with national standards: GB/T19502-2004 "General Principles for Surface Chemical Analysis - Glow Discharge Atomic Emission Spectroscopy", GB/T22368-2008 "Determination of Multielement Content in Low Alloy Steel - Glow Discharge Atomic Emission Spectroscopy (Conventional Method)", and GB/T22462-2008 "Quantitative Determination of Element Depth Distribution in Nanoscale and Submicroscale Thin Films on Steel Surface - Glow Discharge Atomic Emission Spectroscopy".

0765 259 545

AU8000 Precious Metal Analyzer Model: AU8000 SooHow - China Instrument configuration 1. Si-PIN semiconductor detector, digital multi-channel analysis system, X-ray tube, high and low voltage power supply; 2. Collimator filter system, sample observation system, electronic control system, computer and printer. This product meets the requirements of the national standard GB/T18043-2013 for instrument resolution. AU8000 uses Si-Pin semiconductor detectors, which are far superior to proportional counting detectors; it accurately analyzes the content of gold, silver, platinum, palladium, copper, zinc and nickel in gold, platinum and K-gold jewelry.

0765 259 545